China Glass Factory · Philippines · Fire-rated glass

Fire-Rated Glass for the Philippines

E, EW and EI classifications · Rated as a system, not as a pane · Priced against your drawing

We supply fire-rated glass to Philippine commercial projects in the E, EW and EI classifications. E blocks flames and smoke only, EW adds radiant heat, EI adds the unexposed-face temperature rise. A pane alone is not a fire barrier — the frame, fixings and seal decide the rating, so we quote glass and system together. Priced against your drawing.

Talk to the factory directly

Quote against your drawing within one working day. Send the glass schedule, build-up and destination port.

WhatsApp / phone: +86 138 3303 3053

Email: info@cnglassworks.com

What drives the price of fire-rated glass?

Fire-rated glass is priced per panel and per system, because a rated pane fitted into an unrated frame does not carry a rating at all.

Cost componentWhat it coversWhat moves it
Glass typeSpecially tempered borosilicate, or intumescent-layeredClassification and period — EI 120 costs several times E 30
Frame and fixingSteel or timber frame, setting blocks, intumescent sealWhether the system is supplied as a tested assembly or the glass goes into a third-party frame
DocumentationTest reports and classification certificates per batchWhether the project needs project-specific certification or accepts the type-test report
Packing and freightISPM 15 crates, sea freight to ManilaPanel size and quantity

Send the fire strategy drawing and the required classification per location. Written price and system requirement within one working day.

Fire-rated glass price Philippines: Price from USD ___ per sqm FOB Qinzhou. E, EW and EI sit at different price points, and the frame and seal are costed with the glass, not after it.

What fire-rated glass do you supply?

ItemRange
E (integrity only)E 30, E 60, E 90, E 120
EW (integrity + radiation)EW 30, EW 60
EI (integrity + insulation)EI 15, EI 30, EI 60, EI 90, EI 120
Glass typesSpecially tempered borosilicate, intumescent-layered, wired
FinishClear, textured, or with a printed border
ApplicationDoors, partitions, corridor glazing, stairwells, facades
StandardEN 1363 test, EN 13501 classification

E, EW and EI — what actually differs?

Most specification errors come from treating these three as interchangeable. They answer different questions.

ClassBlocksWhere it is used
EFlames and smoke. No limit on heat transfer.Where the only requirement is stopping fire spread — a glazed screen in a compartment wall, with nobody expected to stand close to it.
EWFlames and smoke, plus a limit on radiant heat through the glass.Escape routes and corridors, where people pass within a metre of the glass and radiant heat would make the route unusable.
EIFlames, smoke, and a limit on the temperature rise on the unexposed face.Stairwells, protected lobbies, and anywhere the far side must stay below the ignition temperature of materials behind it.

If the drawing says "fire-rated glass" without a class, the specification is incomplete. It is the difference between a pane that costs a fraction and one that costs several times as much, and the wrong one will fail inspection.

Why does the frame decide the rating?

A fire test is run on an assembly, not on a pane. That means the glass, the frame, the setting blocks, the clearance and the intumescent seal are tested together, and the certificate names all of them.

We state plainly what we can supply as a tested assembly and what has to come from the frame supplier. We do not describe a glass-only supply as a rated system.

Questions Philippine buyers ask first

What is the difference between E, EW and EI fire-rated glass?

E blocks flames and smoke only. EW adds a limit on radiant heat through the glass. EI adds a limit on the temperature rise on the unexposed face. Escape routes normally need EW or EI; a compartment screen with nobody standing close may only need E.

Can I just replace the glass in an existing frame?

Only if the frame and fixing are the ones named in the test report. A fire rating is issued to an assembly, so putting rated glass into an untested frame removes the rating. The frame supplier has to confirm the detail.

Do you supply the frame as well?

We supply the glass, and we state the frame and fixing requirements from the test report at quotation stage. Where a project needs a complete tested system, we say so at enquiry rather than after the order — it changes who is responsible for the certificate.

Maximum panel size for fire-rated glass?

It depends on the type and thickness. Intumescent-layered products are limited by the laminate; borosilicate is limited by the tempering furnace. Send the opening sizes and we will confirm per location rather than quote a blanket maximum.

Send the drawing, we will send a price

Tell us the build-up, the quantity and the destination port. You get a specification review and a written price within one working day — reviewed by an engineer, not a bot.

WhatsApp · info@cnglassworks.com · +86 138 3303 3053

Other glass we ship to the Philippines

Read next: EI, EW and E explained in detail Fire-rated glass product range Buying checklist before you pay

Lead times on this page were verified against factory records in November 2026. Prices are issued only against a drawing or glass schedule, in writing, and are valid for 30 days from issue.