China Glass Factory · Philippines · Low-E glass

Low-E Coated Glass for the Philippines

Solar control for a hot humid climate · Off-line capped at 3,210 × 6,000 mm · Priced against your schedule

We supply Low-E coated glass for Philippine commercial facades, where the coating keeps solar heat out, not warmth in. Off-line coated panels are capped at 3,210 × 6,000 mm by the coating line, so anything larger needs another route. Coating is applied before tempering, and the edge deleted before the unit is sealed. Priced against your glass schedule.

Talk to the factory directly

Quote against your drawing within one working day. Send the glass schedule, build-up and destination port.

WhatsApp / phone: +86 138 3303 3053

Email: info@cnglassworks.com

What drives the price of Low-E glass?

Low-E is a coating operation on top of a glass operation, and the coating line's size limit is what usually decides the price rather than the glass itself.

Cost componentWhat it coversWhat moves it
Base glassClear, low-iron or tinted floatWhether a neutral colour is required, which pushes towards low-iron
CoatingOff-line sputtered or on-line pyrolyticOff-line performs better but is capped at 3,210 × 6,000 mm and needs edge deletion; on-line is durable and can be used monolithic
Edge deletionRemoving the coating from the sealing zoneRequired for off-line coated glass going into a sealed unit — skipping it causes seal failure
Packing and freightISPM 15 crates, sea freightWhether the panel ships monolithic or as a sealed unit

Send the elevation, the target SHGC and the destination port. Written price within one working day.

Low-E glass price Philippines: Price from USD ___ per sqm FOB Qinzhou. Coating type, light transmission and whether the unit is monolithic or sealed change the number, so we quote per schedule.

What Low-E glass do you supply, and in what sizes?

ItemRange
Coating typeOff-line (sputtered, soft coat) or on-line (pyrolytic, hard coat)
Off-line maximum panel3,210 × 6,000 mm
Thickness4, 5, 6, 8, 10, 12 mm
Base glassClear, low-iron, tinted
Performance dataSHGC, U-value, visible light transmission to EN 410 / EN 673
Build-upsMonolithic (on-line only), or sealed unit with argon
EdgeCoating deleted at the sealing zone for off-line coated units

The 3,210 × 6,000 mm ceiling is the coating line, not the tempering furnace. A 12 m jumbo panel cannot be off-line coated.

Why do Philippine facades want a different Low-E?

A European specification optimises for keeping heat in. In Manila the load is reversed, and copying a European coated product usually produces a facade that is too dark and still too hot.

Off-line or on-line — which Low-E should I choose?

PropertyOff-line (sputtered)On-line (pyrolytic)
PerformanceBetter SHGC and U-value for the same VLTModerate, but stable
DurabilitySoft coat — must be inside a sealed unit, edge deletedHard coat — can be monolithic and exposed
Maximum panel3,210 × 6,000 mmLarger, limited by the float line
Best forSealed units in a curtain wall, where performance is the driverMonolithic retrofit glazing, or where a hard coat is needed

Questions Philippine buyers ask first

Can Low-E glass be tempered?

Off-line coated glass is coated first, then tempered, and the coating is designed to survive the tempering cycle. On-line coated glass can also be tempered. What cannot happen is coating a panel after tempering — so the order of operations is fixed, and it is why the size limit comes from the coating line.

Why is the maximum Low-E panel only 3,210 × 6,000 mm?

Because the sputtering line is smaller than the tempering furnace. If a project needs a 12 m coated panel, it cannot be made off-line. The alternatives are an on-line hard coat, a tinted body glass, or a split panel with a visible joint.

How long does the coating last?

An off-line soft coat sealed inside a unit lasts the life of the unit, provided the edge is deleted and the seal is intact. An exposed soft coat at an edge or a monolithic installation degrades within a few years in coastal humidity. On-line hard coats are durable enough to be exposed.

Do I need argon with Low-E?

For a U-value target below about 1.8 W/m²K, yes. Low-E alone reduces radiant transfer; argon reduces conductive transfer through the cavity. The two are normally specified together.

Send the drawing, we will send a price

Tell us the build-up, the quantity and the destination port. You get a specification review and a written price within one working day — reviewed by an engineer, not a bot.

WhatsApp · info@cnglassworks.com · +86 138 3303 3053

Other glass we ship to the Philippines

Read next: Low-E glass product range How IGU U-value is calculated Buying checklist before you pay

Lead times on this page were verified against factory records in November 2026. Prices are issued only against a drawing or glass schedule, in writing, and are valid for 30 days from issue.