Glass Partitions for Philippine Offices, Clinics and Shops
China Glass Factory is a glass factory in Qinzhou, China, supplying tempered glass partitions, frameless or framed, to Philippine offices, banks, clinics and shop fit-outs. We cut, polish, drill and temper panels from 4 mm to 19 mm, up to 3,660 × 12,000 mm, with 7–15 day production and export packing built for the Manila, Cebu and Davao run.
Send thickness, panel sizes and destination port — quote within 24 hours.
What thickness should a glass partition be?
| Thickness | Build-up | Where it is used | Note |
|---|---|---|---|
| 4 mm (5/32 in) | Single | Not a partition on its own | Only as a laminated inner ply or a cabinet back |
| 5–6 mm (3/16–1/4 in) | Single or 5+5 laminated | Small fixed screen, shop display backing | Too flexible above 1.2 m wide without a frame |
| 8 mm (5/16 in) | Single, framed | Budget office cubicle, half-height screen | Cheapest option that still passes as safety glass |
| 10 mm (3/8 in) | Single, frameless | The default for frameless office partitions | Patch fittings or a top and bottom channel |
| 12 mm (1/2 in) | Single, frameless | Full-height partition, partition door leaf, panels over 3 m | Stiff enough to hang a door without a frame |
| 15 mm (5/8 in) | Single | Structural glazing, tall lobby screen | Needs engineered fixings, not patch fittings |
| 19 mm (3/4 in) | Single | Glass floor, stair tread, point-fixed wall | Structural design required |
| 5+5 / 6+6 laminated | PVB 0.76–1.52 mm | Acoustic partition, overhead glass, door leaf | Stays in the frame if it breaks |
| 6+12A+6 IGU | Sealed unit | External partition, air-conditioned boundary | Heat and noise together |
Two rules that decide the job more often than the thickness does:
- Frameless height. A 10 mm frameless panel is comfortable to about 3,000 mm. Above that the panel deflects and the joints open — go to 12 mm and add a top channel, or break the wall into two tiers with a transom.
- A door changes everything. A frameless swing door in a partition needs a 12 mm leaf with patch hinges; the fixed panels beside it stay at 10 mm. Putting a door in a 10 mm wall is the single most common mistake we see on drawings sent to us from Manila.
Framed, frameless or demountable — which type fits your opening?
| Type | How it is fixed | Best for | What to send us |
|---|---|---|---|
| Frameless | Patch fittings, top and bottom channel, or point fixings | Offices, clinics, showrooms — the clean look | Height, width, and whether there is a door |
| Semi-frameless | Aluminium U-channel top and bottom only | Budget fit-outs, half-height screens | Channel width so we can size the glass to fit it |
| Framed | Full aluminium frame supplied locally | Wet areas, high-traffic corridors | Frame rebate depth |
| Demountable | Proprietary post-and-glass system | Rental floors that get reconfigured | The system brand — we cut to its module |
| Sliding / top-hung | Track and rollers, glass drilled for fittings | Small offices, consultation rooms | Track type and the clear opening you want |
We supply the glass only: cut, edge-polished, holes and notches drilled, then tempered. Frames, patch fittings, hinges and tracks are bought locally or imported by your contractor — we will confirm the hole pattern against the hardware drawing you send.
How much noise does a glass partition actually block?
Sound reduction is where most partition quotes go wrong, because the frame and the seals matter as much as the glass.
| Build-up | Rw (laboratory) | What it feels like |
|---|---|---|
| 10 mm single | about 31 dB | Normal speech audible as a murmur next door |
| 12 mm single | about 33 dB | Meeting room to corridor, workable |
| 6+6 laminated, 1.52 PVB | about 38 dB | Two adjacent offices, conversation not understood |
| 6+12A+6 IGU | about 35 dB | External wall of a call centre |
| 5+5 laminated + 50 mm air gap + 5+5 | about 45 dB | Studio, clinic consultation room |
Rule of thumb: if privacy matters, seal the perimeter first and buy laminated second. A 12 mm panel in a frame with a 5 mm gap around it performs worse than a 10 mm panel with proper gaskets. Figures above are published laboratory values for the glass alone, not a site test.
How is the glass packed and delivered to the Philippines?
| Item | Detail |
|---|---|
| Packing | Cork pads between panels, edge protectors on all four sides, individual foam wrap, fumigated timber crate, steel banding |
| Standing | Panels travel on edge, never flat — flat stacking is how partition glass arrives chipped |
| Marking | Every crate labelled with the room, the panel number and the measured size, matching the cutting list |
| Loading | Photographs of every crate and every container |
| Port of loading | Qinzhou / Beihai |
| Production | 7–15 days after deposit |
| Minimum | One 20GP, or a mixed 40HQ with other glass in the same container |
| Documents | FORM E prepared by us under the ASEAN–China FTA; packing list per crate |
| Destination | Covers | Production | Sea transit | Clearance |
|---|---|---|---|---|
| Manila | Metro Manila, Cavite, Laguna, Batangas, Clark, Subic | 7–15 days | 5–10 days | 3–7 days |
| Cebu | Cebu, Iloilo, Bacolod, Bohol | 7–15 days | 5–10 days + 2–4 days feeder | 3–7 days |
| Davao | Davao, Cagayan de Oro, General Santos | 7–15 days | 5–10 days + 3–5 days feeder | 3–7 days |
Transit figures are the forwarder's numbers for the Qinzhou–Manila lane; the feeder add-on for Cebu and Davao is confirmed against the booking at quotation, because it depends on which carrier takes the container that week. We do not quote a transit time we cannot book.
What else do buyers call a glass partition?
- glass partition — general term, the one this page is built on
- glass wall / glass room divider — same product, home and office renovation searches
- office partition glass / office glass partition — commercial fit-out searches
- demountable glass partition — the rental-floor, reconfigurable version
- frameless glass partition — the patch-fitting look
- glass cubicle / glass cabin — the small enclosed version
- toughened glass partition — the British and Philippine site usage of "tempered"
- acoustic glass partition — when the search is about noise, not looks
- fluted / frosted glass partition — privacy without losing light
All of the above are cut from the same 4–19 mm range at the same factory. If your drawing says "toughened" and our quote says "tempered", it is the same glass.
Get a glass partition quotation
| Channel | Response | Detail |
|---|---|---|
| Viber | Within 2 hours in working hours | PENDING — Viber number to be supplied |
| Messenger | Within 2 hours in working hours | PENDING — page link to be supplied |
| Phone | Working hours | +86 138 3303 3053 |
| Within 24 hours | info@cnglassworks.com |
Three numbers give you a firm price: thickness, each panel width × height and piece count, destination port (Manila / Cebu / Davao). With those three we return an FOB Qinzhou or CIF price in USD within 24 hours.
Questions Philippine buyers ask first
How much does a glass partition cost per square metre in the Philippines?
We quote per project, not per square metre, because the price moves with thickness, hole count, edge work and packing. As an order-of-magnitude: a 10 mm frameless single-glazed partition is the cheapest build that still looks frameless, and a 6+6 laminated acoustic build is roughly double the glass cost of the 10 mm single. Send the drawing and we return an itemised price within one working day.
Can you make a frameless partition 3.5 metres high?
Yes, but not in 10 mm. Above 3,000 mm we move to 12 mm with a top channel, or split the wall at 2,400–2,800 mm with a transom. A 10 mm panel at 3.5 m high deflects under hand pressure and the vertical joints open within a year — this is the failure we are asked to replace most often.
What is the minimum order for a custom partition?
There is no fixed minimum. One 20GP is fine, and partition glass is often shipped inside a mixed 40HQ together with tempered, laminated or mirror glass. A single-room order is uneconomic only because of crating and freight, not because of a factory minimum.
Related glass
- Tempered glass — why a partition must be tempered
- Laminated glass for acoustic and safety builds
- Glass supplier Manila — local delivery and stock
- All glass types supplied to the Philippines
Request a glass partition quotation — send thickness, panel sizes and destination port.